Auweld Premium Welding Cable

Auweld Welding Cable – Blue is suitable for regular duty usage. The Auweld Cables are are available in conductor areas from 10 mm² to 185 mm² and sold in 100m per spool.

Please contact us for further inquiries including product variety, replacement parts and product details.
Clear

Description

Auweld Welding Cable – Blue is suitable for regular duty usage. The Auweld Cables are are available in conductor areas from 10 mm² to 185 mm² and sold in 100m per spool.

Material Features

Conductor

0.2 mm stranded Copper-Cladded
Aluminium (CCA) in tightly bonded braids

Sheath

Heavy duty heat, fire, oil resistant PVC, meter marked

Voltage Drop

When total cable length exceeds 10 meters, we recommend using the next larger size cable to minimise voltage drop and maintain adequate welding current.

Features

  • CCA wires are lighter and less tiring to work with at heights
  • Good conductivity, durability and flexibility
  • Reliable flexibility and conductivity
  • Strong resistance against oil, chemicals and solvents
  • Flame retardant

Specification

PRODUCT NO. NOMINAL CONDUCTOR AREA (MM²) NOMINAL OVERALL DIAMETER (MM) NOMINAL COPPER DIAMETER (MM) NOMINAL THICKNESS OF INSULATION (MM) NO. OF WIRE X WIRE DIAMETER (MM) CONDUCTOR RESISTANCE
Ω/KM @ 20°C
260310102 10 8.2 4.7 2.4 322/0.2 1.91
260315162 16 9.3 5.9 2.5 513/0.2 1.21
260320252 25 10.65 7.3 2.6 798/0.2 0.78
260330352 35 11.8 8.5 2.7 1,121/0.2 0.55
260340502 50 13.7 10.2 2.8 1,596/0.2 0.39
260350702 70 15.92 12.1 2.8 2,220/0.2 0.27
260360952 95 18.2 14 3.0 2,997/0.2 0.21
260370122 120 19.10 15.8 3.2 1,702/0.3 0.16
260380152 150 24.55 17.7 3.4 2,146/0.3 0.13
 260390182 185 26.40 19.4 3.7 1,443/0.4 0.11

DUTY CYCLE (IEC245-82)

  • Continuous 100%
  • Heavy 60%
  • Light industrial 30%
  • Limited input 25%

The typical duty cycles for various welding processes and applications are as follows:
Automatic welding: Up to 100%
Semi-automatic welding: 30% to 85%
Manual welding: 0% to 60%

AMBIENT TEMPERATURE (°C) 20°C 25°C 30°C 35°C 40°C 45°C 50°C 55°C 60°C 65°C
 RATING FACTOR 1.04 1.00 0.96 0.91 0.87 0.82 0.76 0.69 0.64 0.57

Description

Auweld Welding Cable – Blue is suitable for regular duty usage. The Auweld Cables are are available in conductor areas from 10 mm² to 185 mm² and sold in 100m per spool.

Material Features

Conductor

0.2 mm stranded Copper-Cladded
Aluminium (CCA) in tightly bonded braids

Sheath

Heavy duty heat, fire, oil resistant PVC, meter marked

Voltage Drop

When total cable length exceeds 10 meters, we recommend using the next larger size cable to minimise voltage drop and maintain adequate welding current.

Features

  • CCA wires are lighter and less tiring to work with at heights
  • Good conductivity, durability and flexibility
  • Reliable flexibility and conductivity
  • Strong resistance against oil, chemicals and solvents
  • Flame retardant

Specification

PRODUCT NO. NOMINAL CONDUCTOR AREA (MM²) NOMINAL OVERALL DIAMETER (MM) NOMINAL COPPER DIAMETER (MM) NOMINAL THICKNESS OF INSULATION (MM) NO. OF WIRE X WIRE DIAMETER (MM) CONDUCTOR RESISTANCE
Ω/KM @ 20°C
260310102 10 8.2 4.7 2.4 322/0.2 1.91
260315162 16 9.3 5.9 2.5 513/0.2 1.21
260320252 25 10.65 7.3 2.6 798/0.2 0.78
260330352 35 11.8 8.5 2.7 1,121/0.2 0.55
260340502 50 13.7 10.2 2.8 1,596/0.2 0.39
260350702 70 15.92 12.1 2.8 2,220/0.2 0.27
260360952 95 18.2 14 3.0 2,997/0.2 0.21
260370122 120 19.10 15.8 3.2 1,702/0.3 0.16
260380152 150 24.55 17.7 3.4 2,146/0.3 0.13
 260390182 185 26.40 19.4 3.7 1,443/0.4 0.11

DUTY CYCLE (IEC245-82)

  • Continuous 100%
  • Heavy 60%
  • Light industrial 30%
  • Limited input 25%

The typical duty cycles for various welding processes and applications are as follows:
Automatic welding: Up to 100%
Semi-automatic welding: 30% to 85%
Manual welding: 0% to 60%

AMBIENT TEMPERATURE (°C) 20°C 25°C 30°C 35°C 40°C 45°C 50°C 55°C 60°C 65°C
 RATING FACTOR 1.04 1.00 0.96 0.91 0.87 0.82 0.76 0.69 0.64 0.57